Pertimbangan laboratoris arah pemasangan rotasi gigitiruan sebagian lepasan rangka logam Laboratory considerations in rotational path of insertion of metal frame removable partial denture

Abstract

Clinical indications and contraindications for insertion path of removable partial denture (RPD)have been welldiscussed in the literature. However, specific discussion of proper laboratory technique and procedure for dentaltechnician is scarce and limited. This article describes two problems that dental technicians occasionally encounterwhich make the fabrication of rotational insertion path of RPD difficult or impossible. Design modifications by theclinician can eliminate problems faced by technicians in determining the proper path of insertion. Lack of clinicalexperience and/or guidance from the literature related to the insertion path of RPD design may cause laboratoryand clinical problems. The recognition of these potential problems will minimize the laboratory and clinicalproblems
Section

References

  1. Loney RW. Removable partial denture manual. Dalhous: John Wright & Sons Ltd.; 2010. hal. 63-4.
  2. Moon HK, Seong JH. Full mouth rehabilitation of destroyed dentition with rotational removable partial denture: a case report. J Prosthet Dent 2010;94: 46-9.
  3. Jennifer SS, Edward JB. Rotational path removable partial denture (RPDs): Conservative esthetic treatment option for the edentulous mandibular anterior egion: A case report. 2008; 20 (2): 98-105.
  4. McGivney GP, Carr AB. McCracken’s removable partial prosthodontics. 10th ed. St. Louis: The CV Mosby Co.; 2000. hal. 164-8.
  5. Ivanhoe JR. Laboratory considerations in rotational path removable partial denture. J Prosthet Dent 2000; 84: 470-2.
  6. Jacobsen TE. Rotational path partial denture design: A 10 years clinical follow up - Part I. J Prosthet Dent 2005; 71 (3): 271-7.
  7. Jepson NJA. Removable partial dentures. London: Quintessence Publishing Co. Ltd.; 2004. Hal. 70-2.
  8. Jones JD, Garcia LT. Removable partial dentures: A clinical guide. Iowa: John Willy & Sons Ltd.; 2009. hal. 39-41.
  9. Krol AJ. Clasp design for extension base removable partial denture. J Prosthet Dent 2003; 29: 408-15.

How to Cite

Soesetijo, F. A. (2011). Pertimbangan laboratoris arah pemasangan rotasi gigitiruan sebagian lepasan rangka logam Laboratory considerations in rotational path of insertion of metal frame removable partial denture. Journal of Dentomaxillofacial Science, 10(2), 120–123. https://doi.org/10.15562/jdmfs.v10i2.268

HTML
528

Total
3448

Share

Search Panel